Journal of Radiological Protection|Whole-body counter survey results 4 months after the Fukushima Dai-ichi NPP accident in Minamisoma City, Fukushima [PDF]

Submitted by RIJS on
Item Description
Abstract Using the first WBC unit installed in Fukushima Prefecture after the accident, the radiocesium body burdens of 566 high-risk residents of Minamisoma city were measured in July 2011 at the Minamisoma Municipal General Hospital. The analysis of the data was challenging because this chair-type, WBC unit, did not have sufficient shielding against background gamma rays and methods had to be developed to reliably compensate for the body-attenuated background radiation. Fortunately, data for repeated tests of hospital staff members using both the chair-type and well-shielded FASTSCAN WBC units, installed in September 2011, were available and could be used to check the validity of the analysis. The CEDs of all subjects, estimated under the assumption of acute inhalation in March 2011, were found to be less than 1 mSv.
Translation Approval
Off
Internet Archive Flag
Flagged for Internet Archive
Media Type
Layer Type
Archive
Seeds
Location
0,0
Media Creator Username
RIJS
Media Creator Realname
KH
Frequency
Archive Once
Scope
One Page
Internet Archive Status
Verified
Language
English
Notes
https://partner.archive-it.org/1131/collections/7472/crawl/944789
Media Date Create
Retweet
Off
English Title
Journal of Radiological Protection|Whole-body counter survey results 4 months after the Fukushima Dai-ichi NPP accident in Minamisoma City, Fukushima [PDF]
English Description
Abstract Using the first WBC unit installed in Fukushima Prefecture after the accident, the radiocesium body burdens of 566 high-risk residents of Minamisoma city were measured in July 2011 at the Minamisoma Municipal General Hospital. The analysis of the data was challenging because this chair-type, WBC unit, did not have sufficient shielding against background gamma rays and methods had to be developed to reliably compensate for the body-attenuated background radiation. Fortunately, data for repeated tests of hospital staff members using both the chair-type and well-shielded FASTSCAN WBC units, installed in September 2011, were available and could be used to check the validity of the analysis. The CEDs of all subjects, estimated under the assumption of acute inhalation in March 2011, were found to be less than 1 mSv.
Flagged for Internet Archive
Off
URI
http://wayback.archive-it.org/7472/20160601000000/https://iopscience.iop.org/article/10.1088/0952-4746/34/4/787/pdf
Attribution URI
https://iopscience.iop.org/article/10.1088/0952-4746/34/4/787/pdf